Leave Your Message

20kv-high-voltage-oil-immersed-distribution-transformer

20kv-high-voltage-oil-immersed-distribution-transformer.jpg

20KV High Voltage Oil-immersed Distribution Transformer

Our high voltage oil-immersed distribution transformer is designed for use in industrial settings such as real estate, petroleum, metallurgy, chemical, and light industries. With a rated working voltage of 20KV and suitable for AC 50HZ power systems, this transformer is a reliable and efficient solution for your power distribution needs.

    Product Application

    This transformer is ideal for use in a wide range of industrial applications, including but not limited to real estate developments, oil refineries, metal smelting plants, chemical processing facilities, and light industrial complexes. It is specifically engineered to meet the demanding power distribution requirements of these industries, ensuring stable and efficient electricity supply.

    Product Advantages

    ● High-quality magnetic grain-oriented silicon steel is used for optimal performance and energy efficiency.
    ● The coil winding is crafted from premium raw materials using the latest technology, ensuring reliability and longevity.
    ● Equipped with a pressure release valve, the 30-2000KVA transformer ensures safe operation under varying load conditions.
    ● The transformer is fitted with an oil temperature monitoring device to prevent overheating and ensure operational safety.
    ● The corrugated surface of the oil tank, coated with a dust spraying process, enhances heat dissipation for improved performance.
    ● Utilizing vacuum oil injection technology, the transformer achieves higher insulation performance by eliminating contact with air.

    Product Features

    ● High-quality materials and advanced technology ensure superior performance and durability.
    ● Safety features such as pressure release valves and oil temperature monitoring enhance operational reliability.
    ● The innovative design of the oil tank improves heat dissipation, contributing to the transformer’s efficiency.
    ● Vacuum oil injection technology enhances insulation performance, ensuring reliable and safe operation.
    In conclusion, our high voltage oil-immersed distribution transformer is a versatile and dependable solution for industrial power distribution needs. With its advanced features, high-quality materials, and safety enhancements, it offers a reliable and efficient power distribution solution for a wide range of industrial applications.

    Normal service conditions

    Altitude
    No more than 1000m;
    Environmental temperature:
    The maximum temperature is+40℃;
    The maximum monthly average temperature is +30℃;
    The maximum annual average temperature is +20℃;
    The outdoor minimum temperature is -25℃。
    The waveform of power supply voltage is similar to sine wave.
    For three-phase transformer,its three-phase supply voltage should be approximately symmetrical. Installation environment:
    There is no obvious pollution in the installation envionment;
    The ground  acceleration ag  caused by earthquake is lower than 3m/s²in the horizontal direction and 1.5m/s² in the vertical direction.

    Executive standard

    GB/T1094.1    GB/T1094.2     GB/T1094.3     GB/T1094.5
    GB/T25289     GB/T6451        GB/T7595        GB20052
    JB/T3837       JB/T10088        IEC60076
    The transformer products produced by our company all meet the latest version of the above   standards.

    Special Conditions of Use

    Any special use conditions that need to meet the normal use conditions of the transformer shall be stated in the inquiry and order.

    Ordering instructions

    When ordering,the product model,rated capacity,rated voltage of high and low voltage,high voltage distribution range,phase number,frequency,connection group label,etc.shall be  provided.

    Model and meaning

    20KV-High-Voltage-Oil-immersed-Distribution-Transformer3iv

    20kV Oil-immersed power transformer

    Technical parameters of 20kV S11 series oil-immersed non-excitation voltage regulating transformer
    Rated capacity kV.A Voltage combination kV Connecting group   No-load loss kW   Load loss kW No-load current % Short-circuit impedance %
    High  voltage High voltage tap range Low voltage
    30  20 ±5h
    ±2×25
    0.4 Dyn11
    Yzn11
    Yyn0
    0.10 0.69/0.66 2.1 5.5
    50 0.13 1.01/0.96 2.0
    63 0.15 1.20/1.15 1.9
    80 0.18 1.44/1.37 1.8
    100 0.20 1.73/1.65 1.6
    125 0.24 2.08/1.98 1.5
    160 0.29 2.54/2.42 1.4
    200 0.34 3.00/2.86 1.3
    250 0.40 3.52/3.35 1.2
    315 0.48 4.21/4.01 1.1
    400 0.57 4.97/4.73 1.0
    500 0.68 5.94/5.66 1.0
    630 0.81 6.82 0.9 6.0
    800 0.98 8.25 0.8
    1000 1.15 11.33 0.7
    1250 1.38 13.20 0.7
    1600 1.66 15.95 0.6
    2000 1.95 19.14 0.6
    2500 2.34 22.22 0.5
    Note:
    ① For three-phase transformers with rated capacity of500kVA or less,the load loss value above the diagonal line in the table is applicable to Dyn11or Yzn11 connection group,and  the loss value below the diagonal line is applicable to Yyn0 connection group.
    ②  The performance parameters in the table are also applicable to three-phase transformers with high voltage of 20(10)kV.
    Technical parameters of 20kV S12 series oil-immersed non-excitation voltage regulating transformer
    Rated capacity kV.A Voltage combination kV Connecting group   No-load loss kW   Load loss kW No-load current % Short-circuit impedance %
    High  voltage High voltage tap range Low voltage
    30 20 ±5h
    ±2×2.5
    0.4 Dyn11
    Yzn11
    Yyn0
    0.09 0.69/0.66 2.1 5.5
    50 0.12 1.01/0.96 2.0
    63 0.14 1.20/1.15 1.9
    80 0.16 1.44/1.37 1.8
    100 0.18 1.73/1.65 1.6
    125 0.22 2.08/1.98 1.5
    160 0.26 2.54/2.42 1.4
    200 0.31 3.00/2.86 1.3
    250 0.36 3.52/3.35 1.2
    315 0.43 4.21/4.01 1.1
    400 0.51 4.97/4.73 1.0
    500 0.61 5.94/5.66 1.0
    630 0.73 6.82 0.9 6.0
    800 0.88 8.25 0.8
    1000 1.03 11.33 0.7
    1250 1.24 13.20 0.7
    1600 1.49 15.95 0.6
    2000 1.75 19.14 0.6
    2500 2.10 22.22 0.5
    Note:
    ① For three-phase transformers with rated capacity of 500kVA or less,the load loss value above the diagonal line in the table  is  applicable to Dyn11or YZn11 connection group,and the loss value below the diagonal line is applicable to Yyn0 connection group.
    ② The performance parameters in the table are also applicable to three-phase transformers with high voltage of 20(10)kV

    Leave Your Message