Subian Electric manufactures larger distribution transformers including the 1750 kVA rating at its Xuzhou factory. This size serves industrial plants, commercial complexes and dense distribution areas, stepping medium voltage – commonly 11kV, 20kV or 33kV – down to the 400V/230V system.

With in-house core and coil production, vacuum processing and complete testing, Subian’s 50,000-square-metre factory delivers 1750 kVA units with guaranteed loss data and routine test reports, supported by 350+ staff and 50+ export countries since 2019.

Send your load profile and primary voltage, and Subian’s engineers will confirm the rating, losses and factory quotation.

Subian Electric ISO9001 CE and UL product certification marks
1750 kVA power transformer testing at Subian
Factory-Direct Manufacturer Since 2019 · 50,000m² · 350+ Staff
50,000m²Manufacturing Base
Up to 110kVType-Tested Capability
350+Employees
50+Countries Served
OEM/ODMSupport
WholesaleSupply

Power & Distribution Transformers Built by Subian

Oil-immersed and dry-type transformers from distribution ratings to several MVA, including 1750 kVA units for industrial and large-load projects.

What Is a 1750 kVA Transformer?

A 1750 kVA transformer is a three-phase unit rated for 1750 kilovolt-amperes, typically installed where a medium-voltage supply feeds a large low-voltage load: industrial plants, data centres, commercial complexes and distribution substations. It delivers about 1.4 MW at a typical 0.8 power factor.

At this size the transformer is a major asset, so specification focuses on loss efficiency, impedance matching with the network, cooling and the protection scheme around it. Most 1750 kVA units are oil-immersed for outdoor installation, with dry-type options where indoor fire rules apply.

Pad Mounted Three - Phase Transformer manufactured by Subian Electric
Pad Mounted Three - Phase Transformer manufactured by Subian Electric

What Buyers Check Before Ordering

  • 1.4 MW class at 0.8 pf – serves large industrial and commercial loads.
  • 11 / 20 / 33 kV primaries – with 400V/230V or custom secondaries.
  • Oil-immersed standard – dry-type for indoor duty.
  • Loss-optimised designs – options to meet efficiency targets.
  • Full test documentation – type and routine test evidence supplied.
  • Project engineering – impedance and protection coordination support.

Configuration Options

Installation site, fire rules and network practice decide the configuration:

Oil-immersed outdoor type - Wholesale 1750 Kva Transformer

Oil-immersed outdoor type

Oil-immersed

the standard for substations and plant yards.


ONAN / IEC 60076-1 / 30-2,500 kVA

See the range

Dry-type indoor unit - Wholesale 1750 Kva Transformer

Dry-type indoor unit

Dry-type

for high-rise, tunnel and fire-sensitive sites.


Class F or H / IEC 60076-11 / AN or AF

See the range

Custom impedance & tappings - Wholesale 1750 Kva Transformer

Custom impedance & tappings

Configuration

matched to the network and load flow study.


IEC / project specification

See the range

1750 kVA Transformer Technical Data

Parameter Specification
Rated capacity 1,750 kVA, three-phase
Primary voltage 11 / 20 / 33 kV (per project)
Secondary voltage 0.4 kV or custom
Cooling ONAN / ONAF options (oil) · air (dry)
Vector group Dyn11 / Dyn5 / Ynd11
Impedance per network study (typically 6-8%)
Standard IEC 60076 / GB 1094

Loading and Current Data for Planning

At 0.8 power factor the unit delivers about 1,400 kW; full-load current on the 400V secondary is about 2,526 A per phase, on an 11kV primary about 92 A, and on a 33kV primary about 31 A. The secondary current normally requires busbar or multiple cables per phase rather than a single feeder.

Because the secondary current is high, the LV switchgear, busbar and cable terminations must be designed for the rating and its fault level. Subian’s drawings include the terminal arrangement so the LV package can be engineered in parallel with the transformer order.

Indicative full-load figures

Secondary 400 V approx. 2,526 A per phase
Primary 11 kV approx. 92 A
Primary 33 kV approx. 31 A
Real load at 0.8 pf approx. 1,400 kW

How to Compare Wholesale 1750 Kva Transformer Suppliers

Quotations for this equipment often look identical on the first page. The difference sits in what is attached behind the number, and in the three or four lines that decide the installed cost rather than the purchase price.

What to compareWhat a thin quotation leaves outWhat to ask for
Price basisOne figure, no IncotermEx-works, FOB or CIF, and which port
Payment termsA deposit with no securityT/T split, LC at sight or LC 90 days, and the bank
Lead timeWeeks counted from the orderDays from drawing approval, with the approval date named
Scope of accessoriesCore and coils onlyBushings, tap changer, surge arresters, terminal box and oil charge
Test witnessA report sent after shipmentFAT date agreed at approval, with the witness named
WarrantyA period with no remedy definedDuration, what is covered, and who pays freight on a claim

Buyers who compare on price alone usually discover the gap at commissioning. The six lines above are the ones that decide whether the unit or the panel can be energised without site work. OEM and ODM supply is available where the nameplate, manual and packing have to carry a different brand.

Where These Units Ship

Equipment of this class is usually bought in small batches, tested at the factory and shipped as one consignment. Three references show how buyers in different markets specify it.

ProjectLocationApplicationSupply model
Pad-mounted units for a solar stationEcuadorPhotovoltaic generationDirect export
Utility distribution transformer supplyVenezuelaUtility distributionDirect export
33kV main transformer ODM projectZimbabweMiningODM supply

Scope, packing and delivery notes for each project are in the project case library. Send the single-line diagram and the destination port and the reply follows the same structure.

Large Transformer Production and Testing

Larger ratings are built on the same controlled lines with additional process checks, and every unit is fully tested before dispatch.

1750 kVA Transformer Price & Quotation

Send your load data and primary voltage, and Subian’s engineers will confirm the rating, impedance, losses and a written factory quotation with delivery for your project.

OEM / ODM & Project Supply

EPC contractors and industrial buyers take 1750 kVA units as part of complete electrical packages.

OEM / ODM

OEM / ODM

Factory-Direct

Custom designs integrated into project packages.


Factory direct · Test docs · Export support

Project Supply

Project Supply

Bundled Supply

Transformers, switchgear and panels coordinated from one factory.


Factory direct · Test docs · Export support

Distributor Support

Distributor Support

Channel Partners

Technical data and tender documentation.


Factory direct · Test docs · Export support

Choosing Between Nearby Ratings

Ratings near 1750 kVA include 1600 kVA and 2000 kVA in standard lists. The 1750 kVA unit suits projects whose calculated load sits between those values, or where the network operator accepts non-standard ratings with confirmed losses.

For a large single load the choice also depends on the impedance and short-circuit level the network can accept – a higher kVA at low impedance may raise fault levels beyond the switchgear rating. Subian’s engineers review the load flow before confirming the economical rating.

Product comparison and selection guide
Factory suppliers and manufacturers in China

Choosing a Supplier for This Rating

For a unit of this size, compare the guaranteed losses, the impedance range, the cooling margin and the manufacturer’s type-test evidence. Ask for reference deliveries of similar ratings and for the test format the project consultant requires.

Subian manufactures under ISO9001, ISO14001, ISO45001, CE and UL certified systems with a 110 kV type-test report in the documentation set, and supports projects with drawings, loss data and commissioning documentation.

Confirm delivery and handling: large transformers need transport planning, and a factory that coordinates packing, lifting and site delivery saves the buyer real time.

Certifications & Quality Assurance

Subian’s transformer production runs under ISO9001, ISO14001 and ISO45001 systems with CE and UL certification and type-test evidence to 110 kV class.

Product Certifications

 
FAQs

1750 kVA Transformer Manufacturers & Suppliers FAQ

Questions about the 1750 kVA rating, its loading and project specification.

How many kW can a 1750 kVA transformer supply?
About 1,400 kW at a typical 0.8 power factor, up to 1,750 kW at unity. The kVA figure is the apparent-power limit; kW depends on the power factor of the connected load.
What is the full-load current of a 1750 kVA transformer?
About 2,526 A per phase on a 400V secondary, roughly 92 A on an 11kV primary and about 31 A on 33kV. The LV current needs busbar or multiple cables per phase.
Is 1750 kVA a standard rating?
It is a common project rating; standard preferred lists in some regions use 1600 kVA and 2000 kVA. Subian builds 1750 kVA as a standard platform and can confirm the closest economical rating for your load profile.
Oil-immersed or dry-type at this rating?
For outdoor substation installation the oil-immersed unit is the standard, economical choice. Where indoor installation is required by site fire rules, a dry-type unit is supplied – it is larger and costs more per kVA but removes oil handling from the building.
What documents come with a 1750 kVA transformer?
The routine test report, outline and terminal drawings, loss data, and installation and maintenance instructions. Type-test reports and project documentation can be provided to the consultant’s format for approval.
What information is needed to quote Wholesale 1750 Kva Transformer?
Primary and secondary voltage, connection group, impedance, the required loss level, the mounting arrangement and the destination port. With those six items the quotation can be written against a specification instead of a catalogue page.
Do you build Wholesale 1750 Kva Transformer to a customer’s nameplate?
Yes. OEM and ODM supply covers the nameplate, the manual, the terminal markings and the packing, so the unit arrives under the buyer’s brand. Drawings are approved before winding starts.

Contact Subian

Need the Right Specification?

Tell Subian your target market, product type, quantity and technical requirements. Subian’s team will help you identify a suitable configuration for your project.