Leave Your Message

Products

Vacuum circuit breaker for switchgear--Indoor Electrical 50Hz VCB VS1 Vacuum circuit breaker for switchgearVacuum circuit breaker for switchgear--Indoor Electrical 50Hz VCB VS1 Vacuum circuit breaker for switchgear
01

Vacuum circuit breaker for switchgear--Indoor Electrical 50Hz VCB VS1 Vacuum circuit breaker for switchgear

2025-03-24

It can be used in industrial and mining enterprises, power plants and substations for the control and protection of electrical facilities, and is suitable for places with frequent operations

view detail
Outdoor Vacuum Circuit Breaker--ZW8-12 Outdoor Vacuum Circuit BreakerOutdoor Vacuum Circuit Breaker--ZW8-12 Outdoor Vacuum Circuit Breaker
02

Outdoor Vacuum Circuit Breaker--ZW8-12 Outdoor Vacuum Circuit Breaker

2025-03-24
When the circuit breaker receives a tripping signal, the operating mechanism acts, causing the moving contact to move from the closed position to the open position. At the moment when the moving and fixed contacts separate, an arc is generated due to the increase in the contact resistance between the contacts.

 

The vacuum environment in the vacuum interrupter enables the arc to be quickly extinguished when the current crosses zero, thus achieving the disconnection of the circuit.

 

During the closing process, the operating mechanism makes the moving contact move towards the fixed contact until they come into contact and complete the closing operation, thereby connecting the circuit.
view detail
Outdoor Vacuum Circuit Breaker--ZW20-12 Outdoor Vacuum Circuit BreakerOutdoor Vacuum Circuit Breaker--ZW20-12 Outdoor Vacuum Circuit Breaker
03

Outdoor Vacuum Circuit Breaker--ZW20-12 Outdoor Vacuum Circuit Breaker

2025-03-24
When the circuit breaker receives a tripping signal, the operating mechanism acts, causing the moving contact to move from the closed position to the open position. At the moment when the moving and fixed contacts separate, an arc is generated due to the increase in the contact resistance between the contacts.

 

The vacuum environment in the vacuum interrupter enables the arc to be quickly extinguished when the current crosses zero, thus achieving the disconnection of the circuit.

 

During the closing process, the operating mechanism makes the moving contact move towards the fixed contact until they come into contact and complete the closing operation, thereby connecting the circuit.
view detail
Outdoor Vacuum Circuit Breaker--ZW32-24Outdoor Vacuum Circuit Breaker--ZW32-24
04

Outdoor Vacuum Circuit Breaker--ZW32-24

2025-03-24
When the circuit breaker receives a tripping signal, the operating mechanism acts, causing the moving contact to move from the closed position to the open position. At the moment when the moving and fixed contacts separate, an arc is generated due to the increase in the contact resistance between the contacts.

 

The vacuum environment in the vacuum interrupter enables the arc to be quickly extinguished when the current crosses zero, thus achieving the disconnection of the circuit.

 

During the closing process, the operating mechanism makes the moving contact move towards the fixed contact until they come into contact and complete the closing operation, thereby connecting the circuit.
view detail
Outdoor Vacuum Circuit Breaker--ZW32Y-12Outdoor Vacuum Circuit Breaker--ZW32Y-12
05

Outdoor Vacuum Circuit Breaker--ZW32Y-12

2025-03-24
ZW32Y-12/630-20/25 outdoor permanent magnetic MV vacuum on pillar dry circuit breaker (hereinafter referred to as circuit breaker), is the control and protection equipment used in rated voltage 12KV, 50HZ AC three phase high voltage distribution grid. Mainly used for load current, overload current and short-circuit current breaking, closing in the power lines. Applied to substation and industrial and mining enterprises in power system used for protection and control purposes
view detail
outdoor vacuum circuit breaker--ZW32-12outdoor vacuum circuit breaker--ZW32-12
06

outdoor vacuum circuit breaker--ZW32-12

2025-03-24
When the circuit breaker receives a tripping signal, the operating mechanism acts, causing the moving contact to move from the closed position to the open position. At the moment when the moving and fixed contacts separate, an arc is generated due to the increase in the contact resistance between the contacts.

 

The vacuum environment in the vacuum interrupter enables the arc to be quickly extinguished when the current crosses zero, thus achieving the disconnection of the circuit.

 

During the closing process, the operating mechanism makes the moving contact move towards the fixed contact until they come into contact and complete the closing operation, thereby connecting the circuit.
view detail
Outdoor Vacuum Circuit Breaker--ZW7-40.5Outdoor Vacuum Circuit Breaker--ZW7-40.5
07

Outdoor Vacuum Circuit Breaker--ZW7-40.5

2025-03-25

The ZW7 - 40.5 outdoor high - voltage vacuum circuit breaker is an outdoor high - voltage electrical device designed for three - phase alternating current at 50Hz with a rated voltage of 40.5kV. It is equipped with a spring operating mechanism or an electromagnetic operating mechanism, allowing for remote electric opening and closing operations, as well as local manual energy storage and manual opening and closing operations. Its design performance meets the requirements of the GB1984 - 89 "AC High - Voltage Circuit Breakers" standard and complies with the IEC - 56 "AC High - Voltage Circuit Breakers" standard of the International Electrotechnical Commission. This product is mainly used for the control and protection of outdoor 35kV power transmission and distribution systems. It is also suitable for normal operation and short - circuit protection in urban and rural power distribution networks and industrial and mining enterprises. It features a porcelain - post structure and is well - suited for frequent operation scenarios.

view detail
Indoor Vacuum Circuit Breaker--ZN85-40.5Indoor Vacuum Circuit Breaker--ZN85-40.5
08

Indoor Vacuum Circuit Breaker--ZN85-40.5

2025-03-25

The ZN85 - 40.5 indoor high - voltage vacuum circuit breaker is suitable for three - phase AC 50Hz power systems with a rated voltage of 40.5kV. It can be used as a protection and control device in industrial and mining enterprises, power plants, and substations, and is suitable for occasions with frequent operations.

view detail
Indoor Lateral Type Vacuum Circuit Breaker--VS1 Series of VcbIndoor Lateral Type Vacuum Circuit Breaker--VS1 Series of Vcb
09

Indoor Lateral Type Vacuum Circuit Breaker--VS1 Series of Vcb

2025-03-25

The VS1 series 4000A indoor lateral - type vacuum circuit breaker is a kind of indoor high - voltage switchgear. It is suitable for three - phase AC 50Hz power systems with a rated voltage of 12kV, used as a protection and control device in power systems such as industrial and mining enterprises, power plants, and substations3. It can be installed in fixed - type switchgear or used alone, and is especially suitable for occasions with frequent operations1. This circuit breaker adopts an integrated design of the operating mechanism and the circuit breaker body. It can be used as a fixed - installation unit or equipped with a special propulsion mechanism to form a hand - cart unit3.

view detail
Vacuum/SF6 Circuit Breaker--LW3-12 630A 3-Pole Outdoor Pole-MountedVacuum/SF6 Circuit Breaker--LW3-12 630A 3-Pole Outdoor Pole-Mounted
10

Vacuum/SF6 Circuit Breaker--LW3-12 630A 3-Pole Outdoor Pole-Mounted

2025-03-25

The LW3 - 12 630A outdoor pole - mounted SF6 circuit breaker is a three - phase AC 50Hz outdoor high - voltage electrical apparatus3. It uses SF6 gas as the arc - extinguishing and insulation medium and adopts a gas - pressure - type arc - extinguishing structure3. It is mainly used in power systems with a rated voltage of 12kV, such as substations and power plants, to switch rated current and short - circuit current, and can also be used as a tie - in circuit breaker and for switching capacitor banks3. With an in - built current transformer for measurement and protection, it is an ideal upgrade product for circuit breakers3.

view detail
Indoor High Voltage  Vacuum Load Break Switch--FZN25 FZRN25 12KV 24kVIndoor High Voltage  Vacuum Load Break Switch--FZN25 FZRN25 12KV 24kV
11

Indoor High Voltage Vacuum Load Break Switch--FZN25 FZRN25 12KV 24kV

2025-03-25
FZN25 and FZRN25 are indoor high - voltage electric three - pole air vacuum load - break switches, which are mainly used in 12kV and 24kV three - phase AC 50Hz power systems. They are designed for the control and protection of electrical equipment in indoor substations, industrial and mining enterprises, and other power distribution systems.
The FZN25 is a basic load - break switch, while the FZRN25 is a combination of a load - break switch and a fuse, which can provide additional over - current protection through the fuse. These switches are usually installed in metal - enclosed switchgear cabinets and can be operated manually or electrically, and can also be used in conjunction with control and protection devices to achieve remote operation and monitoring.
view detail
Outdoor High Voltage Isolating Vacuum Load Switch--FZW32-12 (40.5) typeOutdoor High Voltage Isolating Vacuum Load Switch--FZW32-12 (40.5) type
12

Outdoor High Voltage Isolating Vacuum Load Switch--FZW32-12 (40.5) type

2025-03-25

It is suitable for outdoor three - phase AC power distribution systems with a rated voltage of 12 kV (the 40.5 in the model might be a related parameter or an error in some cases, as the common rated voltage for this type is 12 kV), a rated current of 630 A, and a rated frequency of 50 Hz. It is used to switch and close power distribution lines under load, and can also be used to switch and close no - load lines and no - load transformers. This load switch can be used in the power, metallurgy, mining, chemical industry, and other departments' power transmission and distribution systems to control circuits, and is also suitable for places with frequent operations.

view detail
High Voltage indoor disconnector switch--GN19High Voltage indoor disconnector switch--GN19
13

High Voltage indoor disconnector switch--GN19

2025-03-25

The GN19 high - voltage indoor disconnector switch is a switching device used in high - voltage electrical equipment. It is mainly used to reliably isolate electrical equipment from the live part during power - off maintenance and other situations to ensure the safety of maintenance personnel and the normal maintenance of equipment. It is usually installed in indoor high - voltage switchgear cabinets or substations and is suitable for AC power systems with a rated voltage of 3 - 35 kV and a frequency of 50 Hz.

view detail
outdoor pole mounted disconnect switch--40.5KV 250aoutdoor pole mounted disconnect switch--40.5KV 250a
14

outdoor pole mounted disconnect switch--40.5KV 250a

2025-03-25

The 40.5 - kV 250 - A outdoor pole - mounted disconnect switch is a key electrical device used in outdoor high - voltage power distribution systems. It is mainly installed on poles and is designed to isolate electrical circuits in the power system under normal or maintenance conditions. This switch plays a crucial role in ensuring the safety and reliability of power supply by allowing for the convenient disconnection and connection of power lines when necessary.

view detail
Electrical Transformers--JDZ - 10  Power VoltageElectrical Transformers--JDZ - 10  Power Voltage
15

Electrical Transformers--JDZ - 10 Power Voltage

2025-03-28

The JDZ - 10 is a type of single - phase voltage transformer widely used in the Chinese power system. It is designed to accurately measure and transform high - voltage electrical signals into low - voltage signals that can be safely used by measurement and protection devices. These transformers play a crucial role in power distribution networks, substations, and various electrical equipment monitoring systems.

view detail